Siemens Sinumerik 840C Diagnostics Manual page 172

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

1 Alarms
1.5.1 Alarm description
161003
Function abort due to 611D error ...
Scan
Startup application
Effect
Current startup function aborted
Explanation
A system error has caused the active function to terminate.
Function abort function generator:
S
Function generator already active
S
Wrong mode
S
Selected servo cycle is 0
S
Length of period is 0 or > 1000 s
S
Scaling is negative
S
Amplitude 1 is negative or greater than allowed
S
Offset is beyond the allowed limits
S
Limitation is greater than allowed
S
Wrong curve form
S
Pulse width is negative or greater than the length of period
S
Bandwidth is < 1 or > 100000
S
Calculation of a register length for the noise signal from length of period and bandwidth for which no provision
has been made
S
Scaling change with inactive function generator
Furthermore the following errors (No. and meaning) are possible:
97
"Measuring function 611D aborted with error"
98
"611D ends FG mode, was already active"
99
"No pulse enable"
100
"Timer expired, 611D does not respond"
Function abort measuring functions:
S
Measuring function is already active
S
Measuring type not in permitted range
S
Measured value not input
S
There is a gap in the measured values input
Remedy
Start up control/drive again and repeat procedure
161004
Measurement aborted
Scan
Startup application
Effect
Current measurement aborted
Explanation
Current measurement aborted because of system error
Remedy
Start up control/drive again and repeat procedure
1–164
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96
OK softkey

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents