Siemens Sinumerik 840C Diagnostics Manual page 116

Digital ana module
Hide thumbs Also See for Sinumerik 840C:
Table of Contents

Advertisement

1 Alarms
1.5.1 Alarm description
105056
Log ... cannot be created
Scan
Power up
Effect
Power up without log
Explanation
It was not possible to create a log file (alarm log = 1, service log = 2) (disk defective or full).
Remedy
Check disk
Note
Applies as from SW 4
105057
CAUTION: Virus alarm!!!
Scan
On powering up control after SysLock triggered a virus alarm
Effect
None
Explanation
If the program SysLock finds that the size of the main memory has changed since its first initialization, a virus
alarm is triggered.
Remedy
If this virus alarm is triggered, the system has to be examined and decontaminated with a virus scanner. In order to
allow the virus scanner to work properly, it is essential that the system is started up with a boot disk that is not
infected with a virus.
Note
Alarm from SW 6.3
106000
Listing texts ... cannot be read
Scan
MMC power up
Effect
Listing texts cannot be used.
Explanation
An essential system file cannot be read.
Remedy
Notify service.
Note
Applies as from SW 4
106001
Listing ... being prepared
Scan
Selection of a listing
Effect
The selected listing is prepared just once.
Explanation
This text simply provides information and is intended to explain a delay that might occur. When selecting the same
listing again, this does not have to be prepared again.
Remedy
Wait until the message disappears again.
Note
Applies as from SW 4
106002
... is being read
Scan
File functions MDD
Effect
A data block is being read in from harddisk.
Explanation
This text simply provides information and is intended to explain a delay that might occur.
Remedy
Wait until the message disappears again.
Note
Applies as from SW 4
106003
...: Error in data block ...
Scan
File functions MDD
Effect
A data block has not been completely read in.
Explanation
A data block read in from harddisk (so-called punched tape format) contains an error.
Remedy
Correct the error as far as possible and repeat the process.
Note
Applies as from SW 4
1–108
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
04/96
01/99
OK softkey

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-dSinumerik 840ce

Table of Contents