04/96
105049
Operator panel interface ... faulty
Scan
After Power On
Effect
An interface which does not exist has been set in the config file of the master control
Explanation
Siemens settings apply
Remedy
Set correct interface and Power On
105050
Keyword unknown in line ... (master control)
Scan
After Power On
Effect
An unknown keyword is in the config file of the master control
Explanation
Line is ignored
Remedy
Correct and Power On
105051
Wrong value in ... line (master control)
Scan
After Power On
Effect
An incorrect value stands behind the keyword in the config file of the master control
Explanation
Interpreted as value 0
Remedy
Correct and Power On
105052
Text too long in line ... (master control)
Scan
After Power On
Effect
A string is too long in the config file of the master control
Explanation
Line is ignored
Remedy
Correct and Power On
105053
Missing value in line ... (master control)
Scan
After Power On
Effect
The value behind the keyword is missing in the config file of the master control
Explanation
Line is ignored
Remedy
Correct and Power On
105054
Too many masks in line ... (master control)
Scan
After Power On
Effect
There are too many masks for registering the alarms to be entered in the log in the config file of the master control
Explanation
Line is ignored
Remedy
Reduce number of masks and Power On
105055
Log ... created new
Scan
Power up
Effect
Old entries have been deleted.
Explanation
The existing log (alarm log = 1, service log = 2) could no longer be accessed.
Remedy
Note
Applies as from SW 4
Siemens AG 2001 All rights reserved 6FC5198–jAB40
SINUMERIK 840C / SIMODRIVE 611–D (DA)
1 Alarms
1.5.1 Alarm description
OK softkey
1–107