Servo Amplifier Connection - Mitsubishi Electric GOT1000 Series Handbook

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

4.2.2 Servo amplifier connection

System configuration
1) RS-232
Target device
RS-232
Servo amplifier
O PE N
L 1
L 2
L 3
U
V
W
MELSERVO-J2-Super
series
MELSERVO-J2M
series
MELSERVO-J3
Relay
series
Created by
the user *1
2) RS-422
Target device
RS-422
Created by the user
Servo amplifier
O PE N
RS-422
L 1
L 2
L 3
U
V
W
MELSERVO-J2-Super
series
MELSERVO-J2M
series
MELSERVO-J3
series
Relay
Created by
the user *1
168
4.2 Other MITSUBISHI controllers
4.2.2 Servo amplifier connection
cable
MR-CPCATCBL3M
3M:3m
Created by the user
External connection
GT11H-C -37P
GT11H-C
30:3m 60:6m
30:3m
cable
RS-422 conversion
GT16-C
R4-9S
02:0.2m
Created by the user
Created by the user
External connection
GT11H-C
GT11H-C -37P
30:3m 60:6m
30:3m 60: 6m
100: 10m
100: 10m
Communication unit
Not required
Built in GOT
RS-232
GT15-RS2-9P
Not required
Built in GOT
Not required
Built in GOT
Communication unit
Not required
Built in GOT
RS-422
conversion
GT15-RS2T4-9P
RS-422/485
GT15-RS4-9S
Not required
Built in GOT
Not required
Built in GOT
*1: When using GT11H-C
*2 Use GT15-RS4-9S for using GT155 .
GOT
GT16/GT15
GT11
Handy GOT
GOT
GT16
GT16/GT15
GT11
Handy GOT
-37P

Advertisement

Table of Contents
loading

Table of Contents