(2) GT15
For GT15, the combinations of the bus, network, or Ethernet connection and the serial
connection are available as shown in the following table.
Bus / network / Ethernet connection
• Bus connection
• MELSECNET/H connection (programmable controller to
programmable controller network)
• MELSECNET/10 connection (programmable controller to
programmable controller network)
• CC-Link IE controller network connection
• CC-Link connection (intelligent device station)
• Ethernet connection
• Third party programmable controller connection (Ethernet connection)
• MODBUS
/TCP connection
• Robot controller connection
• CNC connection (MELSECNET/10 connection (programmable
controller to programmable controller network), CC-Link connection
(intelligent device station), Ethernet connection)
The number of channels and the functions that can be used differ depending on the GOT to be used.
The table below shows the allowable combinations of connection types, the number of channels and
restricted functions.
Item
Allowable combination of connection types
• Bus / network / Ethernet connection: 1 channel
(a)
• Serial connection: 1 to 3 channels
(b)
• Serial connection: 4 channels
*1
When the functions below are used, the connectable number of channels may be restricted depending on the
combination of the functions to be used.
•
Bar code function
•
Report function
•
RGB output
•
Functions with the CF card unit or CF card extension unit
•
Ethernet download
Video/RGB display and RGB output cannot be used at the same time.
The CF card unit and the CF card extension unit cannot be used at the same time.
The barcode function, the RFID function, and the remote personal computer operation function can not be
used together.
For details, refer to the following.
*2
When any of the connection methods below is used, Ethernet connection cannot be used although Ethernet
download, gateway function and MES interface function can be used.
•
Bus connection
•
CC-Link IE controller network connection
•
MODBUS
*3
With the barcode function, the RFID function, or the remote personal computer operation function, the FA
transparent function via the RS-232 connection is not available.
•
RFID function
•
Hard copy(For printer output)
•
External I/O/ Operation panel
•
Gateway function
Mounting units on the GOT side interface <GT16/GT15>
•
MELSECTNET/H connection
/TCP connection
Serial connection
• Direct CPU connection
• CC-Link connection (via G4)
• Microcomputer connection
• Inverter connection
• CNC connection (serial connection)
GOT to be used
GT1595
GT1585
GT155
GT157
GT156
Max. 4
Max. 2
channels
channels
Max. 4
Max. 2
channels
channels
•
Remote personal computer operation function
•
MES interface function
•
MELSECNET/10 connection
•
CC-Link connection
3.2 Precautions for Use
• Computer link connection
• Third party programmable
controller connection
(serial connection)
• Temperature controller
connection
• Servo amplifier connection
: Allowed
: Restricted
Functions that are restricted by the
*1*2
connection type
FA transparent function
RS-232
USB
*3
*3
•
Video/RGB display
•
Sound output
1
2
3
4
5
6
7