1. CONNECTION CONFIGURATION

4.1.6 MELSECNET/H connection

System configuration
1) Optical loop
Target device
QCPU
QSCPU
Motion controller
*1*2
CPU(Q series)
Optical fiber
*2
CNC C70
*2
CRnQ-700
A
J61QBT11
C
Network module
2) Coaxial bus
Target device
QCPU
QSCPU
Motion controller
*1*2
CPU(Q series)
Coaxial
*2
CNC C70
*2
CRnQ-700
A
J61QBT11
C
Network module
144
4.1 MITSUBISHI Programmable Controller
4.1.6 MELSECNET/H connection
Cable
Communication unit
MELSEC
NET/H
MELSEC
*3
NET/H
board
Q80BD-J71LP21-25
Q80BD-J71LP21G
Programmable
controller CPU
Cable
Communication unit
MELSEC
NET/H
MELSEC
*3
NET/H
board
Programmable
controller CPU
*1: GT SoftGOT1000 is not available.
*2: Configure the multiple CPU system.
*3: For the cable type to be used, refer to the MELSECNET/H reference manual.
*4: Distance between stations for using the QSI optical cable.The overall extension cable length and
the length between stations differ depending on the cable type to be used and the total number
of stations.For details, refer to the MELSECNET/H reference manual.
*5: When connecting to the Q redundant system, use the version K or later for the MELSECNET/H
board driver (SW0DNC-MNETH-B).
*6: Connect the PC CPU module to another programmable controller,
*7: Distance between stations for using the 5C-2V coaxial cable. The overall extension cable length
and the length between stations differ depending on the cable type to be used and the total
number of stations. For details, refer to the MELSECNET/H reference manual.
GT15-J71LP23-25
*5
DOS/V personal
computer
GOT
PC CPU
MELSECNET/H
module
network module
QJ71LP21-25
RUN
MNG
T.PASS
D.LINK
SD
RD
ERR.
L ERR.
STATION NO.
X10
X1
IN
4
MODE
Install to a PC
OUT
QJ71LP21
-25
CPU module.
GT15-J71BR13
*5
DOS/V personal
computer
Q80BD-J71BR11
GOT
PC CPU
MELSECNET/H
module
network module
QJ71LP21-25
RUN
MNG
T.PASS
D.LINK
SD
RD
ERR.
L ERR.
STATION NO.
X10
X1
IN
4
MODE
Install to a PC
OUT
QJ71LP21
-25
CPU module.
GOT
Max. number of
GOTs connected
63
Max. connection
distance
GT16/GT15
1 km
Max. number of
personal computers
connected
64
GT SoftGOT1000
+
Max. connection
License key for
distance
GT SoftGOT1000
1 km
*6
Max. number of
personal computers
connected
64
GT SoftGOT1000
Max. connection
+
distance
License key for
1 km
GT SoftGOT1000
GOT
Max. number of
GOTs connected
31
Max. connection
distance
GT16/GT15
500 m
Max. number of
personal computers
connected
32
GT SoftGOT1000
Max. connection
+
distance
License key for
500 m
GT SoftGOT1000
Max. number of
*6
personal computers
connected
32
GT SoftGOT1000
Max. connection
+
distance
License key for
500 m
GT SoftGOT1000
*4
*4
*4
*7
*7
*7