Chapter 19—Other Functions
Calibrating the Faders
The DM1000 motorized fader positions may shift over time depending on the operating
conditions and environment. You can correct the shifted faders using the Calibration func-
tion.
1 Make sure that the power to the DM1000 is turned off.
2 While holding down the [ENTER] button, turn on the POWER ON/OFF
switch.
After a moment, the DM1000 displays a message indicating that the calibration is in
progress. Calibration takes about two minutes. It is important that you do not touch the
faders while this message is displayed.
When calibration is finished, the DM1000 displays a page that enables you to fine-tune the
fader position.
3 Follow the instructions on the display and lower all faders to – , then press
[ENTER].
4 Set faders 1–16 to –15 and the Stereo fader to –30, then press [ENTER].
5 Set faders 1–16 to 0, then press [ENTER].
Proceed to the next step without moving the Stereo fader this time.
6 Finally, set faders 1–16 to +10 and the Stereo fader to 0, then press [ENTER].
This is the end of the fader calibration process. The DM1000 restarts in normal mode.