Patching Omni Outs
You can route the DM1000's internal signals to OMNI OUT 1–8.
1 Press the DISPLAY ACCESS [OUTPUT PATCH] button repeatedly until the Out
Patch | Omni Out page appears.
1
The OMNI 1–12 parameter boxes (
eter indicators are explained below:
Parameter values
BUS1–BUS8
AUX1–AUX8
ST L/R
INS CH1–INS CH48
INS BUS1–INS BUS8
INS AUX1–INS AUX8
INS ST-L/ST-R
SURR XXX
("XXX" represents a channel name.)
CR-L/CR-R
CAS BUS1–BUS8
CAS AUX1–AUX8
CAS ST-L/ST-R
CASSOLOL/CASSOLOR
SOLO-L/SOLO-R
M.MX XXX
("XXX" represents a channel name.)
2 Move the cursor to a patch parameter you wish to change, and rotate the
Parameter wheel or press the [INC]/[DEC] buttons to modify the patching.
3 Press [ENTER] to confirm the change.
Tip: You can store the Output Patch settings to the Output Patch library. Refer to Chapter 15
"Libraries" on page 165 for more information.
Output Patching
1
) indicate the currently-patched signals. The param-
Description
No assignment
Bus Out 1–8 signal
Aux Out 1–8 signal
Stereo Out signal
Input Channel 1–48 Insert Out
Bus Out 1–8 Insert Out
Aux Out 1–8 Insert Out
Stereo Out Insert Out
Surround Monitor Outs
Control Room Monitor signals
Bus 1–8 Cascade Outs
Aux Bus 1–8 Cascade Outs
Stereo Bus Cascade Outs
Solo Bus Cascade Outs
Solo Bus signal
Surround Monitor Outs
109