en | Configuration
Menu Items
6 OUTPUT MANAGER
OUTPUT SETTINGS
ENTER OUTPUT No.
OUTPUT EVENT TYPE
OUTPUT AREA / ZONE
OUTPUT MODE
OUTPUT TIME: sec
SIREN SETTINGS
SIREN TIME: min
SIREN BEEP ENABLE
INT SIREN INDIC ON
SIREN OFF ANY KEY
Figure 7.8: Output Manager
2015.05 | 06 | F.01U.309.277
All manuals and user guides at all-guides.com
Parameters / Description
00-not used
01-syst. disarmed
02-system armed
03-sys al audible
04-sys alarm all
05-ext.away siren
06-ext.stay siren
07-int. siren
08-int. sir w.tmp
09-entry/exit del
10-tel.line fault
11-mains
12-battery fault
13-tamper
14-ext. fault
15-all faults
16-fire alarm
17-fire reset
18-away armed
19-stay armed
20-reset
21-follow zn even
22-RF kf button 3
23-RF kf button 4
24-chime indic.
25-verified alarm
26-unverif. alarm
27-technic. alarm
28-bypassed zone
29-ready to arm
30-walk test
31-24 hour alarm
32-panic alarm
33-medical alarm
34-RF power fault
35-follow zone
36-schedule
00 = all/any Area/s 01–16 Area 1-16
0-continuous
1-pulse
2-continuous inv
Master Timer for Outputs
Master Timer for Outputs
0-disable 1-enable
0-disable 1-enable
0-disable 1-enable
Installation Manual
fault
AMAX panel
Certification
Default
000
00
Bosch Sicherheitssysteme GmbH
0
1
1
1