AMAX panel
Condition:
Tamper contact is triggered (if the corresponding zone is programmed as DEOL).
Restore:
4
Supervise:
1.
2.
P
Condition:
Tamper contact (directly connected to the zone) is triggered (zone type = tamper).
Restore:
4
Supervise:
1.
2.
P
Condition:
If the number of incorrect code entries reaches the specified limit (programmed in address
0499), the keypad locks.
Restore:
4
Supervise:
1.
2.
P
Condition:
A receiver is in tamper condition (e.g. when someone removes the device from its base or
pulls it out of the wall) if a wireless module is enabled.
Restore:
4
Supervise:
1.
Bosch Sicherheitssysteme GmbH
All manuals and user guides at all-guides.com
Zone Tamper 1-16 DEOL
Restore the tamper contact and reset the tamper condition.
Report the sensor tamper to configured destination on address 124 when the sensor
tamper is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the tamper condition is reset, send the restored report to the configured
destinations.
The FAULT indicator is turned off when there is no other system fault.
Zone type 1-16 Tamper
Restore the tamper contact and reset the tamper condition.
Report the tamper condition to configured destination on address 124 when the tamper
condition is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the tamper condition is reset, send the restored report to the configured
destinations.
The FAULT indicator is turned off when there is no other system fault.
Keypad Lock out
Wait until the keypad lockout time (3min) expires and reset the fault.
Report the keypad lock out to configured destination on address 124 when the keypad
lock out is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the keypad lock out condition is reset, send the restored report to the configured
destinations.
The FAULT indicator is turned off when there is no other system fault.
RF Receiver Tamper
Restore the receiver and reset the tamper condition. For more information refer to RF
Devices, page 83.
Report receiver tamper fault to configured destination when the fault is detected.