Bosch AMAX panel 2100 Installation Manual page 136

Hide thumbs Also See for AMAX panel 2100:
Table of Contents

Advertisement

136
en | Address Programming
Zone tamper bypass when DEOL zone is bypassed (0 =
disabled, 1 = enabled)
Tamper debounce time (unit: x100s)
Area and Company Name Programming
Option
Area 1 name
Area 2 name
Area 3 name
Area 4 name
Area 5 name
Area 6 name
Area 7 name
Area 8 name
Area 9 name
Area 10 name
Area 11 name
Area 12 name
Area 13 name
Area 14 name
Area 15 name
Area 16 name
Company Name
An area or company name may have up to 18 characters. Each character of the area or
company name uses 2 addresses.
How to insert alphabetical characters via address programming
2
3
4
5
6
2015.05 | 06 | F.01U.309.277
All manuals and user guides at all-guides.com
A character needs two values to provide input to two addresses.
Determine these values using the matrix of table below.
Every character in this table has a row index and also a column index.
Row index is the first, and column index is the second value for each character.
0
1
2
3
!
"
#
0
1
2
3
@
A
B
C
P
Q
R
S
a
b
c
Installation Manual
4
5
6
7
8
$
%
&
'
(
4
5
6
7
8
D
E
F
G
H
T
U
V
W
X
d
e
f
g
h
1603
1
1675 – 1678
0003
Address
Default
2596 – 2615
0
2616 – 2635
0
2636 – 2655
0
2656 – 2675
0
2676 – 2695
0
2696 – 2715
0
2716 – 2735
0
2736 – 2755
0
2756 – 2775
0
2776 – 2795
0
2796 – 2815
0
2816 – 2835
0
2836 – 2855
0
2856 – 2875
0
2876 – 2895
0
2896 – 2915
0
2916 – 2951
0
9
10
11
12
13
)
*
+
-
,
9
:
;
<
=
I
J
K
L
M
Y
Z
[
\
]
i
j
k
l
m
Bosch Sicherheitssysteme GmbH
AMAX panel
14
15
.
/
>
?
N
O
^
_
n
o

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax panel 3000Amax panel 3000 beAmax panel 4000

Table of Contents