76
en | Settings
Depending on the type of the output event, the output parameters can be defined as area
output or follow zone alarm output. The output polarity of each output can be programmed
and defined as one of the following modes: continuous output, pulse output or inverted
output.
The maximum output time is specified by programming and will automatically be reset after
expiration.
Output Events - Overview
Output event
type
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
2015.05 | 06 | F.01U.309.277
All manuals and user guides at all-guides.com
Description
Not Used
System Disarmed
System Armed
System Alarm
System Alarm (audible and silent)
External AWAY Siren
External STAY Siren
Internal Siren
Internal Siren with Tamper
Entry / Exit delay Warning
Telephone Line Fault
AC Power Supply Fault
Low Battery
Tamper
External Fault
All Faults
Fire Alarm
Fire Reset
AWAY Armed
STAY Armed
Reset
Follow Zone Event Zone Number
RF Keyfob Button 3 (e.g. garage
door)
RF Keyfob Button 4 (e.g. light)
Chime Indication
Installation Manual
Output area / zone
No
0 = All areas
1 – 16 = areas 1 – 16*
0 = Any area
1 – 16 = areas 1 – 16*
1 – 16 = areas 1 – 16*
0 = Any area
1 – 16 = areas 1 – 16*
0 = Any area
1 – 16 = areas 1 – 16*
0 = All areas
1 – 16 = areas 1 – 16*
0 = Any area
1 – 16 = areas 1 – 16*
Zone number 1 – 64*
0 = Any area
1 – 16 = areas 1 – 16*