150
en | Troubleshooting
P
Configuration Conflict Sensors
Condition:
A wireless zone configuration is in error condition.
Restore:
4
Supervise:
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
4
P
Configuration Conflict Repeaters
Condition:
A repeater configuration is in error condition.
Restore:
4
Supervise:
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
4
P
Configuration Conflict Keyfobs
Condition:
A keyfob configuration is in error condition.
Restore:
4
Supervise:
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
4
P
2 - Power Failure
Condition:
1.
2.
3.
Restore:
1.
2.
Supervise:
1.
2015.05 | 06 | F.01U.309.277
All manuals and user guides at all-guides.com
The FAULT indicator is turned off when there is no other system fault.
RF Config Failure
Restore all wireless zones to a normal condition and reset the fault. For more
information, refer to RF Devices, page 83.
Reset the fault.
The FAULT indicator is turned off when there is no other system fault.
Restore all repeaters to a normal condition and reset the fault. For more information,
refer to RF Devices, page 83.
Reset the fault.
The FAULT indicator is turned off when there is no other system fault.
Restore all keyfobs to a normal condition and reset the fault. For more information, refer
to RF Devices, page 83.
Reset the fault.
The FAULT indicator is turned off when there is no other system fault.
Panel AC Failure
AC supply deficiency caused by a transformer.
Power supply fuse is broken (230V).
Power supply is disconnected (230V).
Reconnect the AC supply and reset the fault. For more information refer to Installation,
page 26.
Monitor the voltage by MPU.
If the AC supply is not restored one hour after the fault occurred, report the fault to
configured destination on address 124.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).