Bosch AMAX panel 2100 Installation Manual page 72

Hide thumbs Also See for AMAX panel 2100:
Table of Contents

Advertisement

All manuals and user guides at all-guides.com
72
en | Settings
AMAX panel
If this option is enabled, a phone fault indication is restored automatically after the phone is
restored.
If this option is disabled, a phone fault indication has to be reset manually after the phone is
restored.
General Fault Auto Reset
This option enables/disables the automatic general fault reset function.
If this option is enabled, any fault indication is restored automatically after the fault is
restored.
If this option is disabled, any fault indication has to be reset manually after the fault is
restored.
Quick Arming
This option enables/disables the quick arm function via which the user can arm the system by
pressing and holding [*] / [#] for three seconds without entering the code.
Installer Access until Next Arming
Before using installer access, a standard user has to enable installer access first. If the option
installer access until next arming is enabled, installer access permission is limited to next
arming.
Remote IP Access
This option enables/disables the remote IP access. If this option is enabled and a connection
is initiated via the PC software A-Link Plus, the system does not verify the IP address, but
verifies the subscriber ID and the installer code. RPC can not link to the panel via IP.
Force Arm When System Is In Trouble Condition
This option enables/disables the forced arming of an area although it is in a fault or tamper
condition.
Event Record Count per Set/Unset Period
This option defines the maximum number of records for an event within the set / unset period.
Language Version
In this option, the currently used language can be changed to the displayed languages.
Keypad 2 Button Alarm
This option enables/disables the keypad 2 button function:
The emergency alarm is transmitted, if [1] and [3], or [*] and [#] are pressed and held for
three seconds. The fire alarm is transmitted, if [4] and [6] are pressed and held for three
seconds. The silent keypad emergency alarm is transmitted, if [7] and [9] are pressed and
held for three seconds.
System Tamper Indication
System Tamper All Areas
In case of a system tamper event, all keypads indicate an alarm. This option defines the
behavior of the alarm on the keypad for area 01 if the alarm is acknowledged on a master
keypad.