7 7 . . 1 1 . . 3 3 . . 7 7 H H a a r r d d w w a a r r e e S S e e t t u u p p
The H H a a r r d d w w a a r r e e tab is found behind the Menu button. It contains controls to man-
ually operate the various hardware devices.
The Hardware Setup Status (right side panel) gives an
overview of the setup progress.
When all five indicators are green, everything on the
hardware setup page, necessary for a build, has been
completed.
N N o o t t e e
Green indicators indicate that all the neces-
sary steps have been completed. However, it
does not guarantee that the parameters and
the build itself are correct.
7 7 . . 1 1 . . 3 3 . . 7 7 . . 1 1 F F u u n n c c t t i i o o n n s s
S S e e l l e e c c t t F F i i l l a a m m e e n n t t ( ( C C a a t t h h o o d d e e ) )
To change cathode theme if other than default.
S S e e l l e e c c t t t t h h e e m m e e
To select the filament (cathode) theme.
E E d d i i t t t t h h e e m m e e
To be able to edit the filament theme, a master key is required.
Edit the filament (cathode) settings.
C C o o n n f f i i r r m m F F i i l l a a m m e e n n t t ( ( C C a a t t h h o o d d e e ) ) B B u u r r n n T T i i m m e e
Confirm that the burn time of the filament you are going to use is correct by check-
ing the checkbox.
If the burn time has not been confirmed when the vacuum pumps are started, the
"Confirm filament burn time" dialog will be displayed forcing an answer.
N N e e w w c c a a t t h h o o d d e e
When the cathode has been replaced, use this button to reset the burn time.
Selection of this button allows the user to input life cycle details of a previously used
cathode that has been re-installed in the machine.
114
02
OM-710430
en-GB