12. Press S S t t a a r r t t to enable the Power Supply (high volt-
age unit).
The high voltage and cathode current will be
ramped up to operational levels.
13. Wait for the indicator to turn green.
N N o o t t e e
All status indicators (located in the upper right panel) for all tabs must be green to be able to start
the machine.
14. Press S S t t a a r r t t to enable the build.
The start process dialogue appears. Start plate
heating is preselected and necessary when starting
a new build.
15. Press the G G r r e e e e n n t t i i c c k k to accept the start plate
heating.
16. After the system outgassing, remove the start plate
and cathode and put these aside for a possible fu-
ture use.
108
02
OM-710430