AUTODOME 7100i
4.6.7

Alarm Outputs

Idle state
Select Open for the output to operate as a normally open contact, or select Closed if the
output is to operate as a normally closed contact.
Operating mode
Select an operating mode for the relay.
For example, if you want an alarm-activated lamp to stay on after the alarm ends, select
Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select
10 s.
Output name
Enter a name for the alarm output.
This name appears on the Live page.
Note: This name appears in the Digital I/O section of the Live page.
Toggle
Click the button to test the relay / output connection.
4.6.8

Alarm Task Editor

Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
procedure cannot be reversed.
To edit this page, you should have programming knowledge and be familiar with the
information in the Alarm Task Script Language document and the English language.
As an alternative to the alarm settings on the various alarm pages, enter the desired alarm
functions in script form here. This will overwrite all settings and entries on the other alarm
pages.
1.
2.
3.
4.6.9

Alarm Rules

An alarm rule can define which input(s) activate which output(s). Basically, an alarm rule
allows you to configure the device to respond automatically to different alarm inputs.
To configure an alarm rule, specify one input from a physical connection, from a motion
detection trigger, or from a connection to the device's LIVE page. The physical input
connection can be activated by dry contact devices such as pressure pads, door contacts, and
similar devices.
Next, specify up to two (2) rule outputs, or the device's response to the input. Outputs
include a physical alarm output, an AUX command, or a preposition scene.
Select the required Input (a physical alarm connection) from the dropdown list:
Bosch Security Systems B.V.
Monochrome
This switches the camera to the monochrome mode.
Switch mode
When this is selected, you can select the Scene Mode to be used for the active and
inactive period of the alarm.
Click Examples under the Alarm Task Editor field to see some script examples. A new
window opens.
Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your
requirements.
When finished, click Set to transmit the scripts to the device. If the transfer was
successful, the message Script successfully parsed. is displayed over the text field. If it
was not successful, an error message is displayed with further information.