Alarm Inputs; Alarm Outputs; Alarm Task Editor - Bosch FLEXIDOME panoramic 5100i User Manual

Hide thumbs Also See for FLEXIDOME panoramic 5100i:
Table of Contents

Advertisement

42
en | Configuration
4.6.5

Alarm Inputs

Active
Configure the alarm triggers for the unit.
Select N.C. (Normally Closed) if the alarm is to be triggered by opening the contact.
Select N.O. (Normally Open) if the alarm is to be triggered by closing the contact.
Name
Enter a name for the alarm input. This is then displayed below the icon for the alarm input on
the Live page (if configured).
Action
Select a type of action to be performed when an alarm input occurs:
Click Set to apply the changes.
4.6.6

Alarm Outputs

Configure the switching behavior of the output.
Select different events that automatically activate an output. For example, turn on a floodlight
by triggering a motion alarm and then turn the light off again when the alarm has stopped.
Idle state
Select Open for the output to operate as a normally open contact, or select Closed if the
output is to operate as a normally closed contact.
Operating mode
Select the way the output works.
For example, if you want an activated alarm to stay on after the alarm ends, select Bistable. If
you wish an activated alarm to stay on for ten seconds for example, select 10 s.
Output follows
Select the event that triggers the output.
Output name
The alarm output can be assigned a name here. This name appears on the Live page.
Toggle
Click the button to switch the alarm output manually (for example, for testing purposes or to
operate a door opener).
Click Set to apply the changes.
4.6.7

Alarm Task Editor

Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
procedure cannot be reversed.
To edit this page, you should have programming knowledge and be familiar with the
information in the Alarm Task Script Language document and the English language.
As an alternative to the alarm settings on the various alarm pages, enter the desired alarm
functions in script form here. This will overwrite all settings and entries on the other alarm
pages.
2022-10 | V03 | F.01U.385.628
None
Monochrome
This switches the camera to the monochrome mode.
Switch mode
When this is selected, you can select the Scene Mode to be used for the active and
inactive period of the alarm.
User manual
FLEXIDOME panoramic 5100i | FLEXIDOME
panoramic 5100i IR
Bosch Security Systems B.V.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents