Toshiba G3 Workbook page 46

Applications workbook
Table of Contents

Advertisement

Setting
Comments
Value
16
Contact closes to signify inverter overload pre-alarm. Example of inverter overload: G3 is rated for 150% of rated current
for 2 minutes. If drive is operated at 150% of rated current for one minute, the inverter overload is at 50%, or half of its
overload current-time capability. The drive trips on overload at 100%. Inverter overload pre-alarm starts at 50%.
17
Contact closes to signify inverter is not in an overload pre-alarm. Example of inverter overload: G3 is rated for 150% of
rated current for 2 minutes. If drive is operated at 150% of rated current for one minute, the inverter overload is at 50%, or
half of its overload current-time capability. The drive trips on overload at 100%. Inverter overload pre-alarm starts at
50%.
18
Contact closes to signify motor overload pre-alarm. Example of overload: G3 is rated for 150% of rated current for 2
minutes. If drive is operated at 150% of rated current for one minute, the inverter overload is at 50%, or half of its
overload current-time capability. The drive trips on overload at 100%. Overload pre-alarm starts at 50%.
19
Contact closes to signify motor is not in an overload pre-alarm. Example of overload: G3 is rated for 150% of rated
current for 2 minutes. If drive is operated at 150% of rated current for one minute, the inverter overload is at 50%, or half
of its overload current-time capability. The drive trips on overload at 100%. Overload pre-alarm starts at 50%.
20
Contact closes when heatsink reaches 84 degrees C. Contact opens at 80 degrees C after it has closed
21
Contact closes when heatsink is under 84 degrees C. Contact closes at 80 degrees C after it has opened
22
Contact closes when DC bus is 370 VDC (230 V G3) or 740 VDC (460 V G3) or higher
23
Contact closes when DC bus is not 370 VDC (230 V G3) or 740 VDC (460 V G3) or higher
24
Contact closes when DC bus is under 200 VDC (230 V G3) or 380 VDC (460 V G3)
25
Contact closes when DC bus is not under 200 VDC (230 V G3) or 380 VDC (460 V G3)
26
Contact closes when output current is at or greater than the current programmed into Low Current Detection Level
(TERMINAL SELECTION group) for longer than the time programmed in Low Current Detection Time
27
Contact closes when output current is not at or greater than the current programmed into Low Current Detection Level
(TERMINAL SELECTION group) for longer than the time programmed in Low Current Detection Time
28
Contact closes when torque current equals or exceeds the setting programmed into Overtorque Trip Level
(PROTECTION PARAMETERS)
29
Contact closes when torque current does not equal or exceed the setting programmed into Overtorque Trip Level
(PROTECTION PARAMETERS)
30
Contact closes when dynamic braking resistor is half way or more into its overload as calculated by the drive based upon
the setting in Braking Resistor Value and Braking Resistor Power Rating (PROTECTION PARAMETERS group). See
explanation of overload for Setting Value 16 above.
31
Contact closes when dynamic braking resistor is less than half way into its overload as calculated by the drive based upon
the settings in Braking Resistor Value and Braking Resistor Power Rating (PROTECTION PARAMETERS group). See
explanation of overload for Setting Value 17 above.
32
Contact closes when drive is executing an ESTOP
33
Contact closes when drive is not executing an ESTOP
34
Contact closes when drive is executing a retry
35
Contact closes when the drive is not executing a retry
36
Contact closes when drive is running a Pattern Run
37
Contact closes when drive is not running a Pattern Run
38
Contact closes when the error signal calculated by the drive's PID equals or exceeds the value programmed into PID
Deviation Upper Limit or PID Deviation Lower Limit (FEEDBACK PARAMETERS group)
39
Contact closes when the error signal calculated by the drive's PID does not equal or exceed the value programmed into
PID Deviation Upper Limit or PID Deviation Lower Limit (FEEDBACK PARAMETERS group)
For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-
2192