Thirdpartybatteryparameter - Siemens SITOP UPS1600 Equipment Manual

Hide thumbs Also See for SITOP UPS1600:
Table of Contents

Advertisement

Display name
Data type
AlarmLessCapable
Boolean
ModuleDetected
AlarmMoreCapable
Boolean
ModuleDetected
AlarmNewBattery
Boolean
Detected
AlarmUnexpected
Boolean
ModuleDetected
AlarmWrong
Boolean
BatteryConfiguration
Additional parameters
Display name
Data type
BatteryModule
UInt32
IdentNumber
DeviceManual
String
HardwareRevision
String
Manufacturer
LocalizedText
Model
LocalizedText
OrderNumber
String[20]
RevisionCounter
Int32
SerialNumber
String[16]
SlotId
UInt16
SoftwareRevision
Integer
VersionNumber
String
3.10.6.23

ThirdPartyBatteryParameter

Display name
Data type
BatteryCapacitySet-
Float
point
BatteryDefectVoltage
Float
Setpoint
BatteryDurationCon-
UInt16
stantVoltagePhaseSet-
point
BatteryTypeSetpoint
Byte
ChargeCurrentSetpoint Float
OperatingTemperature
Sbyte
Setpoint
StartOfPreserveVoltage
Float
Setpoint
SITOP UPS1600 / BAT1600 / UPS1100
Equipment Manual, 07.2021, A5E37775406-11-76
Definition
Description
PropertyType
Battery module with reduced power detected.
PropertyType
A battery module with excessive power detected.
PropertyType
A new battery was connected. The battery will be included in
the calculation of the total capacity and the charge parame-
ters.
PropertyType
Unexpected module type detected.
PropertyType
Wrong battery configuration
Definition
Description
PropertyType
Module identification number
PropertyType
Address (path in the file system or URL/web address) of the
operating instructions for the unit.
PropertyType
Hardware revision of the device
PropertyType
Name of the company that manufactured the device
PropertyType
Model
PropertyType
Article number
PropertyType
Incremental counter that specifies how often the static data
in the device was modified.
PropertyType
ID, which uniquely identifies the device for the device manu-
facturer
PropertyType
Number of the slot
PropertyType
Revision status of the device software
PropertyType
Software Version (only SITOP BAT1600)
Definition
Description
AnalogItemType
Total capacity of the installed batteries in Ah.
AnalogItemType
Voltage value below which a battery is considered to be
defective and should no longer be charged.
AnalogItemType
Duration of the constant voltage charging phase.
PropertyType
Make/type of battery 0 ... lead-gel battery (Pb), 1 ... pure
lead battery (pPb)
AnalogItemType
Max. permissible current to charge the battery
AnalogItemType
Typical ambient temperatures for battery modules in opera-
tion.
AnalogItemType
Threshold when switching over from normal battery charg-
ing to preserve charge voltage (brief post charging).
Engineering and remote access
3.10 OPC UA server
177