9- -2
Ethernet Job Listing
Job Listing
Error Listing
Message Data Output
List of Communicating Stations
Ethadr: 00-60-34-00-08-1F IP-Adr: 142.2.26.144 Timer: 0
Ethadr: 00-60-34-00-08-0B IP-Adr: 142.2.26.146 Timer: 0
Ethadr: 00-60-34-00-08-0A IP-Adr: 142.2.26.145 Timer: 0
Ethadr: AA-00-04-00-02-40 IP-Adr: 142.2.1.100
Ethadr: 00-00-0C-4E-58-0D IP-Adr: 142.2.1.102
...
Job listing is switched on and off with the T-button.
During switch-on and switch-off, error listing, too, is switched on and off with
the T-button. If job listing is enabled, the middle segment at the upper seg-
ment display is activated.
Error listing is switched on and off with the E-button.
Error listing can only be switched on if job listing is switched off. If error listing
is enabled, the lower segment at the upper segment display is activated.
With job listing, only client and server commands are output. In addition, the
O-button is used for switching on and off the output of the message data.
The message data output is only effective if job listing is switched on.
Via the K- or the C-button, the list of communicating stations is output. This
list contains the assignment of the Ethernet address to the IP address.
In addition, the list of communicating stations contains information about
whether the list entry is free or reserved and for how long the entry is still go-
ing to be valid. The timer is set to the value of the retransmission timer by
client jobs.
If an external communication station uses a password, 'attached' is dis-
played.
Example:
act. Serverlist
This list also shows the static part of the ARP table which is preset by the
configuration file.
static
static attached
static
Timer: 52 used attached
Timer: 59 used