5- -4

R5REQ

5.2.2

Output Parameters

P4
High Byte
Code
[hex]
00
No error, correct call
01
Repeat R5REQ call
02
Change PLC program
03
Change protocol parameter
04
The function module R5INIT must be executed
again
05
The function module R5REQ must be executed
again
06
The function module R5CON must be executed
again
07
Reload protocol
P5
Parameter
P4
This is where basic status and error codes that are recognized by the
R5REQ during job allocation are entered:
D The low byte of P4 then contains the status or error code;
D The high byte contains a coded recommendation for a reaction hereto.
PLC Reaction
.
Further error messages that are recognized by the R5REQ during the
start of the job are put into the first word of the corresponding job
block.
Parameter
P5
This is where the user is informed about whether errors have been recog-
nized during job allocation. Each result bit has been assigned a job. The as-
signment corresponds to the one of the P3 input parameter. A set result bit
indicates that the job which has been addressed with the same bit number in
P3 could not be allocated. In addition, a detailed error code is output in the
first word of the relevant job block.
Attribute
Description
W
Error message
Code
[hex]
00
No error, correct call
01
The parameter P3 ABL (Job bit bar) is zero
02
The declared data module is not available
03
The declared data module is too short
04
The declared byte offset is not valid
06
Wrong memory management list, ZS version not
suitable
07
The COM-E is not listed in the SK table
08
Wrong block address of COM-E
Attribute
Description
W
Result bit bar EBL
Low Byte
Error Code
1070 072 196-101 (00.06) GB