9

Ethernet Job Listing

1070 072 196-101 (00.06) GB
The job listing is a local bus monitor which displays all protocol activities as
well as all received and sent commands.
The Ethernet job listing is enabled via the connected terminal at the upper
interface.
For protocol selection for the upper interface, the setting 'no protocol' must
be switched on via the DIP switch S3.
The following keyboard entries are important:
Key
Function
T
Switch on/off job listing
E
Switch on/off error listing, only possible if job listing is switched
off.
D
Display format of Hex/String switch-over for string output
H, ?
Display of allowed key inputs
K, C
Display of the communicating stations, with AST commands
B
Display of the bus parameters and statistics
P
Display of the system modules
I
Input of the Internet address, e.g. 142.2.26.128
N
Input of the module name, string max. 31 characters
M
Display of the message that was output last
If listing is enabled, then the channel 0 for the V.24/20mA protocols
BUEP19E, BUEP64, and BUEP03E is disabled.
Via this interface, the Ethernet protocol software then outputs test mes-
sages. Thus, the user can follow the communication process by connecting
a terminal or a printer, which is a useful tool in the commissioning phase.
.
The job listing function is only intended for usage during commission-
ing because it slows down the data traffic on the Ethernet interface sig-
nificantly.
.
As error messages, mostly Error Class and Error Code are output. The
error and/or the cause of the error can be localized via the error mes-
sage lists in the description of the R5CON module.
Numbers are mostly output in the hexadecimal number system.