Optional Serial Interfaces; General Information; Cfg-Vsn01E1-Nn-Nn-Nn-Nn-Nn-S3 Serial Interface Rs232; Xcom4 On Slot For A6 Extension Card - Bosch Rexroth IndraControl VSB 40.1 Project Planning Manual

Control cabinet pc
Hide thumbs Also See for Rexroth IndraControl VSB 40.1:
Table of Contents

Advertisement

DOK-SUPPL*-VSB*40.1***-PR03-EN-P
Rexroth IndraControl VSB 40.1 Control Cabinet PC
7.3

Optional Serial Interfaces

7.3.1

General Information

General Information
7.3.2

CFG-VSN01E1-NN-NN-NN-NN-NN-S3 Serial Interface RS232

XCOM4 on Slot for A6 Extension Card

XCOM4 on slot for A6 extension
Fig.7-24:
AC 230 V voltage connection via isolating transformer
According to the configuration, serial interfaces are available for the extension
cards A5 and A6 on the slots.
The interfaces have different pin assignments and signal assignments. Before
using the interfaces, identify the type assignment or pin assignment, see the
configuration label on the device (CFG-VSN01E1-xx-xx-xx-xx-xx-xx).
Pin
Assignment
card
1
DCD (Data Carrier Detect)
2
RX (Receive Data)
3
TX (Transmit Data)
4
DTR (Data Terminal Ready)
Bosch Rexroth AG
51/83
PC Box