Panasonic MICRO-IMAGECHECKER AX40 User Manual page 241

Hide thumbs Also See for MICRO-IMAGECHECKER AX40:
Table of Contents

Advertisement

Position Adjustment (Gray Edge), Rotation Adjustment (Gray Edge-Horizontal, Gray
Edge-Vertical)
Sending Command from External device (Command Digit: "Valid")
Communication
Command / Description
direction
Sending Command
from External
device
??: 01 to 99 (Object Checker No.)
aaa: 001 to 255 (Edge Threshold of Horizontal
bbb: 001 to 255 (Edge threshold of Vertical
Response - At
normal operation:
At the end of
??: 01 to 99 (Checker No.)
Change (Command
aaa: 001 to 255 (Edge threshold
Digit: "Valid")
bbb: 001 to 255 (Edge threshold
Response: Error 1
Cause
Response: Error 2
ERROR signal is
output from the
Cause
parallel output port.
*1
If either Horizontal or Vertical is created, specify "0" to the unset edge threshold. (If the
numbers except "0" is specified to the uncreated edge threshold, error response %Z
output). Response to the change command is "0".
Example: checker No. 1 Horizontal- Edge Threshold: 100, Vertical: Unset
Sending Command
% G 0
Response at normal operation
% G 0
% G ?
?
,
a
a
% G ?
?
,
a
a
% U CR
Command in the unspecified form or not provided was received.
Examples:
C
-
%G1,80
(any other checker number than 01 - 99 was specified.)
R
C
-
%B01,80,200
(not provided command)
R
% Z CR
Checker No. specified by a sending command does not include the target checker.
The edge threshold specified by a sending command is not between 001 and 0255 or
001 and 0255.
If an unset threshold is specified to the numbers except "0" when either Horizontal or
Vertical is selected with Position Adjustment (gray edge).
1
,
1
0
0
,
0
1
,
1
0
0
,
0
a
,
b
b
b CR
*1
or Base Checker 1)
*1
or Base Checker 2)
a
,
b
b
b CR
*1
of horizontal or base checker)
*1
of vertical or base checker)
0
0 CR
0
0 CR
C
will be
R
233

Advertisement

Table of Contents
loading

Table of Contents