Gray Edge- Reading Edge Threshold ([%H])
Position Adjustment (Gray Edge), Rotation Adjustment (Gray Scale Edge Horizontal/ Vertical)
Communication
Command / Description
direction
Sending
Command from
External Device
?? : 01 - 99 (To specify the target checker number)
Response - At
Serial setting - Command Digit: "Valid"
normal operation
(Command Digit:
"Valid")
?? : 01 - 99 (Checker No.)
aaa : 001 - 255 (Edge Thresholds of Horizontal
bbb : 001 - 255 (Edge Thresholds of Vertical
Serial setting - Command Digit: Fixed (4 Digit)
?? : 01 - 99(Checker No.)
aaaa : 0001 - 0255 or 1 - 0255
bbbb : 0001 - 0255 or 1 - 0255
nnnn :
nnnn :
Response- Error 1
Cause
Response- Error 2
ERROR signal is
output from the
Cause
parallel output port.
*1 If only Horizontal or Vertical has been set, response for the unset edge threshold will be "0".
Example: If Horizontal-edge threshold = 100 and Vertical = unset (Checker No.)
% H 0 1
,
230
% H
?
? CR
% H
?
?
,
a
a
% H
?
?
a
a
a
*1
(Edge Threshold
(Edge Thresholds
0001 - 0255: If invalid = 0
0001 - 0255: If invalid = space
% U CR
Command in the unspecified form or not provided was received.
Examples:
C
-
%H1
(any other checker number than 01 - 99 was specified.)
R
C
-
%J01
(not provided command)
R
% Z CR
The checker type already created to the specified number is not the target checker of
this command
No checker is created to the specified number.
1 0 0
,
0 0 0 CR
a
,
b
b
b CR
*1
or Base Checker 1)
*1
or Base Checker 2)
a
b
b
b
b CR
of Horizontal or Base Checker 1)
*1
of Vertical or Base Checker 2)