Item
Save
Save Image
Image
Mode
Save Mode
Reset
Image Data
Conversio
CV1 to CV4
n Data
Result
Output
Output
Setting
Settings
Data Type
Output Digit 1 to 11
Invalid Digit Delete/ Zero
PLC Model
Start
Register
Timeout
(ms)
Data Type
Selections
Function
No
Not to save an image in RUN mode.
Per start
To save the image inspected in RUN mode "per start".
Judge. Result
To save the images when a specified arithmetic
expression returns "NG" in RUN mode.
Not Overwrite
To finish saving the images when the number of images
reaches 16.
Overwrite
To continue to save the images by overwriting the image,
to which the smallest number has been assigned, with a
new image when the number of images to be saved
reaches 16.
Display Save
To inspect while the latest save image is displayed. This
Image
feature is available only if a memory image is displayed in
RUN mode.
-
To erase all the save images.
-
To convert the units of calculation results.
For example, conversion from pixel to mm
Not Output
Not to output inspection results
Serial (Per Start)/
To output the selected inspection results to the external
Computer Link/
device.
Serial (Async.)/
Ethernet/ Card
Judgement
To output only the judgement to the external device.
Data Monitor
Among the data quoted to Data Monitor, to output only the
output data that have been set to "On" to the external
device
Both
To output both Judgement Output and Data Monitor
To specify the digit of output data.
To set a process when data digits are less than output
digits.
Panasonic FP/
Output setting: Sets a PLC type for communicating in
MELSEC A+Q/
Computer Link mode.
MELSEC FX/
OMRON
C+CV+CS1/ AB
SLC
0 to 9999
Output setting: Specifies the top number of the target
register to which data are output at the time of setting of
Computer Link.
0 to 20000 ms
To limit the response time from PLC (Output setting =
Computer Link).
16 bit/ 32 bit
To specify an output data length. (Output
setting=Computer Link).
Ref.
page
197
204
152
219
241
187