Re-registering the template- Area Display: Yes
To complete registering the template, send the command from the external device twice.
Communication direction
Sending the Command
from the External Device
(1st. time)
Response (1st time):
Area Display completed.
Sending from external
device (2nd. time)
Response (2nd. time)- At
normal operation:
re-registration completed
Response- Error 1
Response- Error 2
ERROR signal is output
from the parallel output
port.
Processing flow
Command / Description
% A ? ? CR
??: 01 to 99 (To specify the checker number of Smart/Contour Matching)
% A CR
% A CR
% A CR
% U CR
Cause
•
Command in the unspecified form or not provided was received.
•
Examples:
C
% A9
(any other checker number than 01 - 99 was specified.)
R
C
%B01
(not provided command)
R
% Z CR
Cause
•
The checker types already created to the specified numbers are not Smart
Matching or Contour Matching.
•
Template is not registered with the Smart Matching or Contour Matching feature
already created to the specified number.
•
As the image in the re-registration area has no feature, it cannot be registered as
a template.
•
Re-registration positions: Group Position Adjustment (or Rotation Adjustment) is
NG while you select Position Adjustment
•
The positions of group position adjustment (or rotation adjustment) are out of
screen.
225