Panasonic MICRO-IMAGECHECKER AX40 User Manual page 126

Hide thumbs Also See for MICRO-IMAGECHECKER AX40:
Table of Contents

Advertisement

6.12.2 Registering a Base Position
The setting procedure to register the base position of the object is as follows. Before registering a base
position, you can perform a test to check if Horizontal/Vertical Areas can detect an edge. When the image
currently displayed is a live image, import a new image and begin to test. When a Memory image is
displayed, test with the Memory image currently displayed without importing any images.
Registration Procedure
1.
Highlight the "Base Position" tab.
The cursor moves to "Base Setting".
2.
Press the ENTER key.
When the dialog message appears, choose "YES" to continue.
If the edges are correctly detected and the base position is registered, the following data appears.
In the Base Position tab
Corr.: Correspondence value of the first image among the sorted images
Adj. X: 0.0
Adj. Y: 0.0
Base Pos. X: Coordinate X of the first image among the sorted images
Base Pos. Y: Coordinate Y of the first image among the sorted images
In the Message area
Judgement: OK
Corr.: Correspondence value of the first image among the sorted images
Adj. X: 0.0
Adj. Y: 0.0
If the following message appears, it means horizontal and vertical edges are not detected. Check the
setting values of areas (positions of start and end points) or the inspection objects.
E0042 Base position cannot be detected.
118