Changing Max. /Min. Binary Level ([%T])
This is a command to change Max. /Min. Binary Level by specifying a binary label groups A - H. The
max/min. binary level of the currently selected product type can be changed.
Command digit: Valid
Communication
Command / Description
Direction
% T ?
Sending
Command from
External Device
?? : 01 to 08 (To set Binary Level Group No.)
aaa : 001 to 255 (To set Binary Level-Max.)
bbb : 000 to 254 (To set Binary Level-Min.)
% T ?
Response:
Response at
Normal operation
?? : 01 to 08 (Binary Level Group No.)
aaa : 001 to 255 (Binary Level -Max.)
bbb : 000 to 254 (Binary Level-Min.)
% U CR
Response: Error 1
Cause
% Z CR
Response: Error 2
ERROR signal is
output from the
Cause
parallel output port.
To specify the command digit (valid/fixed (4 Digit)), select "ENVIRONMENT" > "Serial Settings" >
"Command Digit" from the menu bar.
?
,
a
a
a
Binary Level Group 2 A
Specified number
01 02 03 04 05 06 07 08
?
,
a
a
a
Command in the unspecified form or not provided was received.
Examples:
C
-
%T1,80,255
(any other checker number than 01 - 08 was specified.)
R
C
-
B01
(not provided command)
R
The max. value of binary level specified by a sending command is smaller than the min.
value of binary Level.
The max. value of binary level is equal to the min. value of that.
Max./min. values of binary level specified by sending command is not between 000 and
255.
,
b
b
b CR
B
C
D
E
F
G
,
b
b
b CR
H