Return value
*1
(HEX)
19460
(4C04
)
H
19461
Axis No. specified in SVST function is invalid.
(4C05
)
H
(The error code returned by the Motion CPU)
19462
 Refer to the manual of the Motion CPU currently used.
(4C06
)
H
19463
(4C07
)
H
A total of 32 or more instructions are simultaneously requested to the Motion CPU
19464
from the programmable controller CPU/C Controller module, and the Motion CPU
(4C08
)
cannot process them. (The error code returned by the Motion CPU)
H
 Refer to the manual of the Motion CPU currently used.
CPU No. of the requesting CPU is incorrect.
19465
(The error code returned by the Motion CPU)
(4C09
)
H
 Refer to the manual of the Motion CPU currently used.
19584
(4C80
)
H
19585
(4C81
)
H
H/W error of the target CPU
19587
(4C83
)
H
19588
(4C84
)
H
-475
Refer to the following.
(FE25
)
 Q Corresponding MELSECNET/H Network System Reference Manual (PLC to
H
to
PLC network)
-3839
 For QnA/Q4AR MELSECNET/10 Network System Reference Manual
(F101
)
 Type MELSECNET/10 Network system (PLC to PLC network) Reference Manual
H
-2174
(F782
)
H
Target station number error
• The target station number is incorrect.
-7656
(E218
)
H
-4097
(EFFF
)
H
Refer to the following.
to
 MELSEC-Q CC-Link IE Controller Network Reference Manual
-8192
(E000
)
H
-8193
(DFFF
)
H
Refer to the following.
to
 MELSEC-Q CC-Link IE Field Network Master/Local Module User's Manual
-12288
(D000
)
H
Refer to the following.
-16386
 MELSEC-Q CC-Link System Master/Local Module User's Manual
(BFFE
)
H
 Control & Communication Link System Master/Local Module type AJ61QBT11/
to
A1SJ61QBT11 User's Manual
-20222
 Control & Communication Link System Master/Local Module type AJ61BT11/
(B102
)
H
A1SJ61BT11 User's Manual
-18558
Target station number error
(B782
)
• The target station number is incorrect.
H
-18572
Target station number error
(B774
)
• A transient request was sent to a non-intelligent device station.
H
-25056
Processing code error
(9E20
)
• The target station cannot process the request.
H
Reset error
• Another task using the same channel executed reset operation while accessing
-26334
other station.
(9922
)
H
• Reset operation was executed during monitoring from Setting/monitoring tools for
the C Controller module.
Routing request error on routing function unsupported station
-26336
• A routing to another loop was requested to the station which does not support the
(9920
)
H
routing function.
424
Error description
Corrective action
Check the user program on C Controller module.
• Check the operating state of the target CPU.
• Take a corrective action in the manual of the target CPU.
Same as in the left.
Check the target station number, and perform the operation again.
Same as in the left.
Check the target station number, and perform the operation again.
• Check the network No. and target station No..
• Check if the target station is an intelligent device station.
• Check the device type.
• Check the station No. and processing code.
• Do not execute the function other than mdTypeRead to other station's I/F
board.
• Retry.
• Monitor again.
Check the routing parameter setting.