Enable Media Patrol
Please be noted that the Auto Rebuild option is also there. Make sure this option is enabled if
you want to automatically start rebuilding a logical drive immediately after the failed drive is
replaced.
21.2

Rebuild a disk array

When you rebuild a disk array, actually you are rebuilding the data on a physical drive.
21.2.1

How to rebuild a disk array

When the logical drive is downgraded or in a critical state, you need to rebuild the array that
contains the drive. If you do not use Auto Rebuild (a spare drive is required), you must rebuild
the array manually after the affected drives have been replaced. Obey the instructions
described here to rebuild a disk array.
By looking at the operational status in the Logical Drives Information display, you get to know
whether the logical drive is in a critical state.
Bosch Security Systems B.V.
To enable Media Patrol, click Background Activities in the Quick Links menu on the
Home page; or click the Subsystem in the tree view, and then click the Background
Activities menu tab. Click to check the Enable Media Patrol option.
To start Media Patrol manually, click the menu expander on the right side of the
Background Activities tab, scroll down and select Start Media Patrol to view the Start
Media Patrol menu. Then click the Start button.
To schedule Media Patrol, click the menu expander to the right of the Scheduler tab,
scroll down, and select Add Media Patrol Schedule to open the Schedule menu. Use this
menu to add a media patrol schedule.
In the event of a physical drive failure in a disk array, if a sufficient spare drive is
available, the disk array automatically begins to rebuild using the spare drive.
If there is no spare drive with sufficient capacity, but the Auto Rebuild function is
enabled, the disk array starts rebuilding automatically after the failed physical drive is
removed and an unconfigured physical drive is installed in the same slot.
If there is no spare drive with sufficient capacity and the Auto Rebuild function is
disabled, you must replace the failed drive with an unconfigured physical drive and
perform a Manual Rebuild.