Figure 5.10: SATA disk drive mounted in a drive carrier
5.4

Management path connection

This section describes how to establish a management connection for the CIP5000
subsystems.
Through the management GUI - a web browser based GUI, you can finish to configure
management path connection.
There are two 1 Gb/s Ethernet RJ-45 ports on the rear panel for connection to an Ethernet
network. After logging into the Management GUI as the administrator, you can change the
network settings.
To connect the server to a local Ethernet for management:
1.
2.
If you have more than one CIP5000 system, host, or server, repeat steps 1 and 2 as instructed.
5.4.1

SAS JBOD expansion

JBOD expansion requires:
Connect to JBOD data path
The SFF-8644 SAS expansion port connector is located on the rear panel of the CIP5000
subsystems (CIP-5316W-00N or CIP-5424W-00N). The controller of the CIP5000 subsystems
manages the CIP-5316-JBOD system, and no additional management connection is required
for the CIP-5316-JBOD system.
Bosch Security Systems B.V.
Attach one end of an Ethernet cable to the network connector or standard NIC in the
Host PC. Attach the other end of the Ethernet cable to one of the ports on the standard
network switch.
Attach one end of an Ethernet cable to one of the ports on the standard network switch.
Attach the other end of the Ethernet cable to an Ethernet port (1000 BASE-T) on the back
of the server.
One or more CIP-5316-JBOD expansion cabinets
One cable from SFF-8644 to SFF-8644 SAS for each CIP-5316-JBOD
Counter-sink screws
(two screws on each side)
User manual
Hardware configuration | en