en | Hardware configuration
Single Controller Expansion
1.
2.
3.
Notice!
When you are ready to power on the CIP5000 subsystems and SAS JBOD expansion cabinets,
first power on the JBOD.
5.5

Connect the power supply

Insert one power cable into the power receptacle for each power supply unit (PSU) and
connect the each PSU to a suitable power source. The enclosure is equipped with two PSU
using an N+1 arrangement.
Each PSU has a status LED. After power on, check the LEDs on each PSU on the rear of the
unit.
These indicators light green to indicate normal operating conditions, and light red to indicate
a problem or unit failure.
Notice!
The CIP-5316W-00N and CIP-5424W-00N is equipped with two PSU using an N+1
arrangement. In this arrangement, one PSU is redundant, so a minimum of one PSU is needed
to power up the enclosure.
2019-10 | V01 | F.01U.380.030
Connect the SFF-8644 SAS port in the host CIP-5316W-00N or CIP-5424W-00N system to
SAS Port 1 on the uppermost CIP-5316-JBOD unit in the rack.
Connect SAS Port 2 on the same CIP-5316-JBOD to the SAS Port 1 on the next CIP-5316-
JBOD in the stack.
Connect the remaining CIP-5316-JBOD enclosures in the same manner.