Sensor Module Cabinet Smc10 / Smc20; Sensor Module Cabinet Smc30 - Siemens Sinamics S120 Comissioning Manual

With startdrive
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

5.2.3.2

Sensor Module Cabinet SMC10 / SMC20

Table 5- 12
Sensor Module Cabinet 10/20 (SMC10/SMC20) – description of the LEDs
LED
Color
State
RDY
off
READY
Green
Continuous
light
Orange
Continuous
light
Red
Continuous
light
Green/
Flashing
red
light 0.5 Hz
Flashing
light 2 Hz
Green/
Flashing
orange
light
or
Red/
orange
5.2.3.3

Sensor Module Cabinet SMC30

Table 5- 13
Meaning of LEDs on the Sensor Module Cabinet SMC30
LED
Color
Status
RDY
Off
READY
Green
Continuous
light
Orange
Continuous
light
Red
Continuous
light
Green/
Flashing
red
light 0.5 Hz
Green/
Flashing
red
light 2 Hz
Commissioning with Startdrive
Commissioning Manual, (IH3), 07/2016, 6SL3097-4AA10-0BP0
Description, cause
Electronic power supply is missing or outside permissible
tolerance range.
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
DRIVE-CLiQ communication is being established.
At least one fault is present in this component.
Note:
LED is controlled irrespective of the corresponding messag-
es being reconfigured.
Firmware is being downloaded.
Firmware download is complete. Wait for POWER ON
Component recognition via LED is activated (p0144).
Note:
Both options depend on the LED status when module
recognition is activated via p0144 = 1.
Description, cause
The electronics power supply is missing or outside the per-
missible tolerance range.
The component is ready for operation. Cyclic DRIVE-CLiQ
communication is taking place.
DRIVE-CLiQ communication is being established.
This component has at least one fault.
Note:
LED is controlled irrespective of the corresponding messag-
es being reconfigured.
Firmware is being downloaded.
Firmware download is complete. The system waits for
POWER ON.
Diagnostics
5.2 Diagnostics using LEDs
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON
147

Advertisement

Table of Contents
loading