Functions

3.20 Coordinate systems

Activating the function
REGIE.INI configuration file section:
[UpperScreen]
; Upper screen area above HMI-Wide-Screen.
; The upper screen area is managed by an independent native windows
; application independently of the REGIE management.
; The upper screen area has an independent softkey area.
; This upper screen softkey area is available only
; on special OEM operator panels.
; Activate this function here
UpperScreen = TRUE
; Announce main window of upper screen,
; to transfer the softkeys from Regie.
; WindowName
UpperScreenWindowName = ""
; Window ClassName
UpperScreenClassName = ""
Operating the HMI program and OEM application
When switching the operation between HMI program and OEM application, use the window
shift key <NEXT WINDOW> or simply click.
The OEM application is either operated by pressing an OEM key (refer below) or with a
mouse click in the main window. All other keyboard entries will now appear in this active
window until one of the function keys (F1-F10, etc.) recognized by the HMI program is
detected. The HMI program is then active again.
The following key combinations are reserved:
<Ctrl+1>, <Ctrl+2>, <Ctrl+3>, <Ctrl+6>, <Ctrl+7>, <Ctrl+8>
3.20
Coordinate systems
3.20.1

Actual value display

Set the following in the display machine data MD9424 $MM_MA_COORDINATE_SYSTEM:
● The position of the workpiece coordinate system (programmed position, corresponds to
● show the holding position of the active tool relative to the workpiece zero in the actual-
48
the default setting) or
value display.