7-12
PC Box
230/115 VAC Power Supply
This connection is used for device variants for 230/115 VAC.
All internally required voltages are generated by the 230/115 VAC power
supply unit.
The supply voltage must comply with
overvoltage category II! Otherwise the
integrated power supply unit might be
destructed.
CAUTION
Use an isolating transformer to generate the
230/115 VAC (see following page).
The 230/115 VAC connection occurs via a 3-pin inlet connector for non-
heating apparatus on the connector panel. The maximum cable cross
section for the connected cables is 1.5 mm
X20
PE
Fig. 7-15:
Pin assignment of the 230/115 VAC connection X20
Parameters
Rated voltage
Power consumption for U
N
Power consumption for U
N
Inrush current for 264 VAC
Overload protection
Short-circuit protection

Fig. 7-16: Technical data 115/230 VAC connection

2
.
Value
85 VAC ... 264 VAC auto range
= 230 VAC
2.5 A
= 115 VAC
5 A
100 A
As of 135 %, deactivation
At all outputs, deactivation
DOK-SUPPL*-VSB*40.1***-PR01-EN-P
VSB 40.1
Assignment
N1
PE
U2
230V_Buchse.cdr