In the same way as when using three Pods, determine the maximum number of simultaneous
mirroring devices connected to the main unit and Pods beforehand as described in "Maximum
number of simultaneous mirroring user devices" (page 21) in the "Active Learning" section.
Next, calculate the network bandwidth that the wireless LAN access point and layer 2 switch
must maintain.
The proposed configuration is listed below.
User devices connected to main unit or Pods: 6 (with image quality set to [High])
Pods: 6
Number of displays connected to the main unit: 2
Bandwidth used by Skype for Business integration: 4 Mbps (Up), 4 Mbps (Down)
Streaming output: Image quality set to [High]
Margin: 30%
For details about calculation equations, see "Network bandwidth" (page 22) in the "Active
Learning" section.
Network bandwidth that the wireless LAN access point must maintain
Calculation equation
Required bandwidth (T
× Number of Pods
+ Total throughput of user devices connected to main unit
= (6 Mbps × 1 + 1 Mbps × 5) × 6
+ (6 Mbps × 2 + 1 Mbps × 4)
= 82 Mbps
Adding the margin of 30%, 82 Mbps × 1.3 = 106.6 Mbps
Network bandwidth that must be maintained between each Pod and layer 2 switch
See "Network bandwidth that must be maintained between each Pod and layer 2 switch" (page
47) in the "Small-scale 3-Pod configuration" section.
Network bandwidth that must be maintained between main unit and layer 2 switch
Calculation equation
Required bandwidth (T
+ Total throughput from Pods to main unit
+ Total throughput from main unit to Pods
+ Total for Skype for Business integration
+ Streaming output
= (6 Mbps × 2 + 1 Mbps × 4)
+ (6 Mbps × 0 + 1 Mbps × 6)
+ (6 Mbps × 6)
+ (4 Mbps + 4 Mbps)
+ 6 Mbps
) = Total throughput of user devices connected to each Pod
wlan
) = Total throughput of user devices connected to main unit
main
(light blue
(Eqn.
B)
(Eqn.
C)
(pink
arrow)
arrow)
48
(Eqn.
A)
(Eqn.
A)
(Eqn.
A)