Symptom
Cannot detect
Device detection by the Vision Exchange App auto search function uses the
main unit or
mDNS protocol. In this protocol, the target devices to detect must exist on
Pods using
the same network.
Vision
mDNS traffic may be blocked on Windows OS devices by the firewall. If
Exchange App
devices cannot be detected using auto search, review the firewall settings.
auto search.
If the user device is running Windows, change the type of "Network
Location" to "Private," and check that the Auto search function operates
correctly.
mDNS traffic is blocked if a network switch or access point connecting the
user device to the main unit or a Pod has IGMP Snooping enabled. If this
occurs, disable IGMP Snooping.
You can also connect, without using auto search, by entering the IP address
directly using Vision Exchange App.
Software
The Windows
keyboard is not
software keyboard
displayed.
specifications
changes after
updating Windows
10 to version 1709.
The software
keyboard was
restored under
Windows 10 version
1709, but the
Windows registry
values for software
keyboards were
reset after
subsequently
running Windows
Update.
Cause
Use the following procedure to check the version of
the OS.
1.
Log in to the OS as an administrator.
2.
Select [Run...] from the [Start] menu.
3.
Enter "winver" and click [OK].
4.
Check the version in the displayed dialog.
If the version is applicable, contact your service
representative. Perform countermeasures to restore
the keyboard.
Perform the same procedure above.
108
Solution