A3: Axis Monitoring, Protection Zones
3.2 Axis monitoring functions
Implementation
①
②
126
1
4
Using the "Park machine axis" function, the user deactivates position measuring system
1:
DB31, ... DBX1.5 (position measuring system 1) = 0
The controller then resets the status signal for the position measuring system:
DB31, ... DBX102.5 (position measuring system 1 activated) == 0
The user waits for the status signal and only now removes the attachment head "B" from
the spindle.
2
3
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Basic Functions