● Code :
A1-1613
● Symptom / Cause :
ITB motor does not operate.
ITB motor is operating but is recognized as stop status
● Troubleshooting method :
1. Turn the machine off. Check if there is any foreign m
2. Remove the ITB unit and reinstall it.
3. Turn the machine on. Is the problem solved?
4. Turn the machine off.
Open the engine/video shield door.
Check if the ITB BLDC motor connector is connecte
If the problem persists, replace the ITB BLDC moto
5. Replace the motor and controller. If the motor opera
● Replacement part
- JC31-00123A (MOTOR BLDC)
- JC96-05689A : CARTRIDGE-TRANSFER ITB
Service Manual
CLX-9250/9350 series
7. Troubles
● Error message :
Actuator Motor Failu
ITB BLDC motor
ITB BLDC motor
7-1
shooting
re #A1-1613: Please open/close door.
s.
matter around the ITB unit.
ed properly.
or. (Refer to 3.8.2 of the chapter 3)
ates normally, replace the ITB unit.