Deleting Tally Generation Settings

1
In the Engineering Setup >Router/Tally >Tally Enable
menu (7364), select the tally generation entry.
2
Press [Delete].
Tally Copy Settings
You can copy the tally information pertaining to a
particular source to a different source.
The settings are common to the parallel and serial tallies.
Making New Tally Copy Settings
1
Open the Engineering Setup >Router/Tally >Tally
Copy >New menu (7365.1).
2
Select the copy-from source.
When setting more than one tally copy, you can
specify the copy-from source start and end addresses.
No.
Parameter
1
Copy From
(From)
2
Copy From
(To)
3
Specify the copy-to source address.
No.
Parameter
3
Copy To
(From)
4
Copy To (To) Copy-to source (end) address
4
Press [Execute].
Modifying Tally Copy Settings
1
Open the Engineering Setup >Router/Tally >Tally
Copy >Modify menu (7365.2).
2
Select the copy source and copy destination.
No.
Parameter
1
Copy From
2
Copy To
376
Tally Copy Settings / Parallel Tally Settings
Adjustment
Copy-from source start address
Copy-from source end address
Adjustment
Copy-to source (start) address
Adjustment
Copy-from source
Copy-to source
3
Press [Execute].
Deleting Tally Copy Settings
1
In the Engineering Setup >Router/Tally >Tally Copy
menu (7365), select the tally copy settings.
2
Press [Delete].
Parallel Tally Settings
This sets the parallel port settings for output of tally
information pertaining to sources and destinations. For
each of the tally output terminal numbers, specify the tally
type, and source address or destination level and address.
Making or Modifying Parallel Tally
Settings
1
In the <Device> group of the Engineering Setup
>Router/Tally >Parallel Tally menu (7366), select
DCU1 or DCU2.
2
Select the slot number and port number.
Notes
When the MKS-2700 is connected, select 2 for the slot
and a value in the range 1 to 36 for the port.
3
Press [Set].
The Set menu (7366.1) appears.
4
In the <Source/Destination> group, select the tally
type.
Src: Returns a tally to all sources output to the
destination.
Dest: Returns a tally to the destination outputting the
source to which a source tally is returned.
5
Set the destination address and level.
The level setting is only required if you selected [Dest]
in step 4.
No.
Parameter
Adjustment
1
Address
Destination address
2
Level
Destination level