Switching Backgrounds Using Dme Wipes - Sony MVS-6520 User Manual

Multi format switcher system with icp-series control panel
Hide thumbs Also See for MVS-6520:
Table of Contents

Advertisement

1
In the Engineering Setup >Switcher >Config menu
(7331), press [PGM Config].
The PGM Config menu (7331.2) appears.
The status area shows the background and key
configuration assigned to the output of each bank.
2
Select the output you want to set.
3
In the <Bkgd> group, select the background.
In Multi Program mode, select [Clean] or [Utility1],
then skip to step 4.
4
In the <Key Enable> group, select [Enable] or
[Disable] for each of the keys.
Setting the key preview configuration
You can make this setting at any time, regardless of the
operation mode.
1
In the Engineering Setup >Switcher >Config menu
(7331), press [K-PVW Config].
The K-PVW Config menu (7331.3) appears.
The status area shows the key preview configuration
for each bank.
2
Select the key preview to set.
3
In the <Mode> group, select [Video] mode or [Key]
mode.
If you select Key mode, skip to step 5.
4
In the <Bkgd> group, select the background.
In Standard mode or Multi Program mode, select
[Clean] or [Utility1], then skip to step 5.
5
In the <Key1> to <Key4> groups, select the
corresponding key status from the following.
Link: Follows the key on/off setting.
On: Key is always on.
Off: Key is always off.
Switching Backgrounds using DME
Wipes
On the MVS-3000 or on the MVS-3000A without an
MKS-6570 installed, a setting must be enabled in order to
use background DME wipes.
This setting can be made for each of the M/E-1 and PGM/
PST banks.
346
Settings for Switcher Configuration
Notes
• Only the background DME wipe or key 1 can be enabled
at any one time.
• If background DME wipe is enabled, side flags cannot
be used in DME wipes.
1
In the Engineering Setup >Switcher >Config menu
(7331), select the target (M/E-1 or PGM/PST) bank.
2
In the <BKGD DME Wipe/Key1> group, select
[BKGD DME Wipe].
Setting User Regions
This assigns the color backgrounds 1 and 2, AUX1 to 24,
and frame memory 1 to 8 for User regions to any of User1
to User8.
Notes
If you change the user region settings, the previously
stored snapshot data and keyframe effect data can no
longer be used.
1
In the Engineering Setup >Switcher >Config menu
(7331), press [User1-8 Config].
The User1-8 Config menu (7331.4) appears.
The status area shows the region names and assigned
user region numbers.
2
Select the region to set.
3
In the <User Region Assign> group, select the user
region you want to assign. If you do not want to assign
a user region, select [No Assign].
4
Repeat steps 2 and 3 as required to make the settings
for other regions.
5
Press [Execute].
6
Check the message, then press [Yes].
Setting the Assignments of DME
Channels
On the MVS-6520/6530/3000A, you can select the DME
channels to use on the M/E and PGM/PST banks for
processed keys or DME wipes.
1
In the Engineering Setup >Switcher >Config menu
(7331), press [DME Config].
The DME Config menu (7331.6) appears.