7
Services Operating Area
7.5 Main services screen
7.5.4

Reading out data via RS-232 interface

Data out
RS 232 C
user
RS 232 C
PG/PC
RS 232 C
printer
Save
settings
Start
Stop
Start
7-266
Function
You can read data out of the control system via the RS-232 interface
to a device (e.g. PC) connected to the interface.
Operating sequence
The interface for your data unit is set correctly.
The "Data out" window is opened.
Via the vertical softkey bar select the interface:
RS-232-C user
RS-232-C PG/PC
RS-232-C printer
Position the cursor on the desired directory in the directory tree.
You return to the overview of the higher level directory by pressing the
"Save settings" softkey.
You can discard your settings by pressing the Recall key.
The data are read out. The message "Transmission in progress" is
displayed.
The display shows "Path/workpiece", "File" and the number of
transmitted "Bytes".
You can interrupt data export at any time by pressing the "Stop" key.
If you press softkey "Start" again, the data export recommences from
the beginning.
SINUMERIK 840D/810D Operator's Guide HMI Embedded (BEM) – 03.04 Edition
7
03.04
 Siemens AG, 2004. All rights reserved