HCSM (Hitachi Compute Systems Manager)
alert message
(1)
Table headings of HCSM alert messages
ID: Message ID
Level: Level of the message: Information; Warning; Error
Message: Alert messages are shown. "X" and "Y" in a message stands for character
strings.
(2)
List of alert messages
ID
Level
FD00
Warning
Description: The temperature of the location shown as Y has reached Warning level. X
shows either Upper (high temperature) or Lower (low temperature) at warning level.
Action: Check if anything interferes with the cooling system since the state may go up to a
higher error level, FD01, although you can keep operations running. When finding some
factors interfering with cooling, such as a malfunction in the cooling equipment or in fan
modules in the system, and dust-covered intake, remove the problem factor. If the
temperature does not return to the normal when you have removed it, contact your reseller or
maintenance personnel.
FD01
Error
Description: The temperature of the location shown as Y has reached Error level. X shows
either Upper (high temperature) or Lower (low temperature) at error level.
Action: The specified module may be stopped for hardware protection. Contact your reseller
or maintenance personnel.
Check if anything interferes with the cooling system. When finding some factors interfering
with cooling, such as a malfunction in the cooling equipment or in fan modules in the system,
and dust-covered intake, remove the problem factor. If the temperature does not return to the
normal when you have removed it, contact your reseller or maintenance personnel.
FD02
Information
Description: The temperature of the location shown as Y has recovered to the normal level. X
shows either Upper (high temperature) or Lower (low temperature) at error or warning level.
Action: None. This is a recovery message.
FD03
Warning
Description: The temperature of the CPU in Location Y has reached Warning level. X shows
either Upper (high temperature) or Lower (low temperature) at warning level.
Action: Check if anything interferes with the cooling system since the state may go up to a
higher error level, FD04, although you can keep operations running. When finding some
factors interfering with cooling, such as malfunction in the cooling equipment or in fan
modules in the system, and dust-covered intake, remove the problem factor. If the
temperature does not return to the normal when you have removed it, contact your reseller or
maintenance personnel.
FD04
Error
Description and Action
Temperature of chassis became warning level. (Temp(X),Location:Y)
Temperature of chassis became error level. (Temp(X),Location:Y)
Temperature of chassis has been restored to a normal level.
(Temp(X),Location:Y)
Temperature of CPU became warning level. (Temp(X),Location:Y)
Temperature of CPU became error level. (Temp(X),Location:Y)