Hitachi Compute Blade 2000 User Manual page 589

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

Partition status is described in the table below: Dictionary status information.
Description of
Item
item
P
Partition number
Power
Power status
Condition
Whether a user
can operate or
not; Fail status.
Status of the
LID lamp
location LED of
the primary blade
Mode
Logical
Partitioning
Auto
Current status of
power on
the power
synchronization
Value
0 to 7
----------
On
Processing power off
Off
Processing power on
ERROR
----------
Normal
FAIL
Initializing
ERROR
----------
On
Off
ERROR
----------
LP
Basic
Initializing
Delaying (Remain
Xmin.)
Waiting
Synchronized
538
Description of value
-
No blade slot assigned
No blade slot installed, which is
assigned
Power-on status
Power is being turned off.
Power-off status
Power is being turned on
Error occurs.
No blade slot assigned
No blade slot installed, which is
assigned
No problem: Available for users
Initialization fails, or the partition
fails.
Just initializing.
Error occurs.
No blade slot assigned
No blade slot installed, which is
assigned
LED is on.
LED is off.
Error occurs.
No blade slot that it belongs to
No blade slot installed, which is
belonged to
Logical Partitioning is Enabled:
LPAR manager boots.
Logical Partitioning is Disabled:
LPAR manager does not boot.
Under initialization
Waiting to complete initialization.
Delaying the power on
Shows how many minutes will take
to power on automatically in
parentheses. If the time left is less
than 1 minute, "Remain 0min." is
displayed.
Waiting to power-on.
Not all modules with the AC power
recovery setting enabled are
supplied with power
Auto power-on is executed.
Synchronized with power supply to
the power supply modules with the
AC power recovery setting
enabled, the auto power-on has
already been executed.

Advertisement

Table of Contents
loading