Hitachi Compute Blade 2000 User Manual page 418

Hide thumbs Also See for Compute Blade 2000:
Table of Contents

Advertisement

Click Next.
9
The following screen appears:
10
With all the RAID disk array configurations selected, specify RAID level, stripe
size, read policy, write policy, and disk array size.
When enabling the write cache of the disk array with the equipment that has no
cache backup module installed, connect the system equipment to UPS. When
you use the equipment without connecting to the UPS, data can disappear and
be corrupted.
Set each item to the following value.
Item
RAID Level
RAID Level
Stripe Size
Stripe size
Access Policy
Access policy
Read Policy
Read policy
Write Policy *1 *2
Write policy
IO Policy
Read-cache operation
NOTICE
Content
[RAID 10]
8 KB
/
16 KB
512 KB / 1 MB
[RW (reading and writing)] /
Read Only (reading only)
Blocked (access denied)
[Normal (no advanced reading)] /
Ahead (always advanced reading)
Without cache backup module installed * 4: [Write
Through (write cache invalid)] /
Always Write Back (write-cache valid) / Write Back
with BBU (Write cache is valid only when the battery
is installed.)
With cache backup module installed * 5:
Through (write-cache invalid)/ Always Write Back
(write-cache
is valid only when a cache backup module is
installed.)]
[Direct (reading from the cache at a cache hit)] /
Cached (always reading from the cache)
367
Setting value **
/
32 KB
/ [64 KB] /
128 KB / 256 KB /
/
valid)/[Write Back With BBU (Write cache