- RAID0 has no data redundancy, and therefore, Rebuild is disabled in the RAID0
configuration. Replace the failed hard disk drive, create the configuration data
again and initialize the hard disk drives. Then recover the data by using backup
data.
Auto rebuild fails:
■ Was a sufficient time taken for hot swap of hard disk drives?
- To allow the auto rebuild to operate correctly, wait at least 90 seconds between
the removal of the failed hard disk drive and the installation of a new hard disk
drive.
■ Is the configuration correct?
Check the auto rebuild settings by using the LSI Software RAID Configuration
Utility.
<Menus to check: Top menu - [Objects] - [Adapter] - [Auto Rebuild]>
* Auto Rebuild cannot be specified in WebBIOS.
A hard disk drive fails:
- Contact your service representative.
Cannot enter standby:
- If you use the LSI Embedded MegaRAID ™ , the system may not enter standby
if there is a heavy I/O.
Cannot enter Hibernation:
- If you use the LSI Embedded MegaRAID ™ , the system may not enter standby
if there is a heavy I/O.
Physical device is not correctly displayed on Universal RAID Utility
- If you use the LSI Embedded MegaRAID ™ , some information on a physical
device may not be correctly displayed on the Universal RAID Utility. It is not a
problem.

Problems with Windows

In some cases, an event log is registered as follows when you install Windows
Server 2003 x64 Editions.
Source: DCOM
Category:Error
Event ID: 10016