3. Installation Procedure

G
Be sure to take the necessary steps to prevent the unit from tipping over.
Use the provided chain. There is a screw located at the top rear of the unit for this purpose.
(1) Remove the screw.
(2) Pass the chain through the screw, then tighten the chain together with the screw in the original screw hole.
(Refer to the installation dimensions diagram.)
(3) Use a tapping screw (4 × × 25: field supply) to fasten the other end of the chain to the wall.
(4) The method used to fasten the chain to the wall varies depending on the type of wall material. Use an
appropriate method to fasten to the wall. (Refer to the examples below.)
Clay wall, plaster wall
Place a wooden support
against the wall, and use a
screw to fasten the
provided chain to the wall.
Mortar concrete wall
Drive a plug for use in concrete
into the wall. Then use
a screw to fasten
the provided chain
to the wall.
Precautions Concerning Opening and Closing the Front Panel
I To open the front upper panel, press at the points
marked "PUSH" on both sides at the top of the panel.
Then tilt the panel and disengage the bottom tabs on
both sides of the panel.
I To open the front lower panel, press at the points
marked "PUSH" on both sides at the top of the panel.
Then tilt the panel and disengage the bottom tabs on
both sides of the panel.
I To close the front upper panel or lower panel, follow the
same procedure as when opening it, but in the reverse
order.
I Remove the front upper panel in order to clean the
outlet filter or set the electrolysis condition.
I Remove the front lower panel in order to clean the
intake filter or remove the drainage tank.
Wooden support
Chain
Plug for concrete
Chain
Plasterboard, thin sheet,
or hollow wall
Drive a plug for use in hollow walls
into the wall. Then use a screw to
fasten the provided chain to the
wall.
* Use a plug that is correct for the thickness of
the wall.
Front upper panel
Front lower panel
Electrolysis condition
setting switch
Intake filter
(Pre-filter, high collection filter)
7 - 4
Installation
Chain
Outlet filter
Drainage tank
7