1. Product Specifications

Model name
General Model No.
Height
External
Width
dimensions
Depth
Net weight
Operating weight
Shipping weight
Shipping volume
Water tank capacity
Exterior color (Munsell number)
Power source
Suitable floor space (approximate)
Power cord length
Control section
Display (LED lamps)
Operation
Operating modes
Service temp. range
Water used
Power consumption
Electrical
characteristics
Current value
Model
Quantity
Rated airflow
Motor output (No. of electrodes)
Louver
Air direction adjustment range
Summer
Continuous
operating time *
3
Winter
Protective device
Water level detection
Sensors
Air filters
Scale filters
Virus Washer element
Operating noise
Water supply method
Drainage method
Primary accessories
Other accessories (options)
High collection fine-particle filter
Model No.
Collection efficiency
Rated airflow
Operating noise
G
Be sure to use normal tap water. Using well water or purified water as-is may cause system failure.
G
In order that this product can remain in good condition and provide many years of reliable service, consumable parts must be
replaced regularly. For details, refer to "Replacing Consumable Parts" in the Instruction Manual that was provided with the system.
G
If the high collection filter is installed, the airflow will be decreased.
*1: Be sure to use normal tap water (drinking water). Depending on the water quality in your area, it may be necessary to
change the system settings. In addition, the tap water in certain areas cannot be used as-is. For details, refer to "Setting the
Electrolysis Condition" and "List of Water Quality Regions" in the Instruction Manual that was provided with the system.
*2: The operating noise was measured in an anechoic chamber. Therefore it is the value at a position 1 m in front of the system
and a height of 1 m. When the unit is actually installed, ambient noise and noise reflection ordinarily result in noise that is
greater than the value indicated here.
*3: Continuous operating time refers to the operating time when the water tank is full (6 L).
Virus Washer System (Floor-Mounted)
mm
mm
mm
kg
kg
kg
3
m
L
Front panel: NW-K11 (VW white), Munsell value N8.5
Side panels: NW-K12 (VW gray), Munsell value N4.0
Single-phase, 220 – 240 V, 50 / 60 Hz
2
m
m
1.7 (parallel plug with grounding contact)
ON/OFF, FAN SPEED, LOUVER, FILTER RESET,
OPERATION, HUMIDITY SAVER, ADD WATER,
DRAIN, FILTER, CHECK, TREATED AIR VOLUME
W
HIGH: 150 / MEDIUM: 80 / LOW: 70
A
HIGH: 2.10 / MEDIUM: 1.20 / LOW: 0.88
3
m
/min
W
2-flap louver (with swing function, fully closed when stopped)
0° – 23° (with air direction position memory)
h
12 (MEDIUM operating speed, air conditions: DB 27°C, RH 47%)
h
10 (MEDIUM operating speed, air conditions: DB 20°C, RH 30%)
Room temp. sensor, water temp. sensor, humidity sensor
Pre-filter (intake side) + High collection filter (intake side)
(collection efficiency: 76% by weight method)
Non-woven cloth filters (composed of 5 layers)
dB (A)
HIGH: 49 / MEDIUM: 35 / LOW: 29 *
Water tank (capacity approximately 6 L)
Drainage tank (capacity approximately 2 L)
Tip-over prevention chain, Instruction Manual, Installation Instructions,
Equivalent to 65% by colorimetric method
%
(equivalent to 93% by weight method)
m
3
/min
dB (A)
HIGH: 49 / MEDIUM: 39 / LOW: 29 *
4 - 2
VW-VF10BG
790
580
297
33
39 (when water tank is full)
36
0.24
Approx. 6
100
CHILD LOCK, DRAIN/DRY
HIGH / MEDIUM / LOW
5 – 35°C
Tap water (drinking water) *
Sirocco fan
1
HIGH: 10 / MEDIUM: 5 / LOW: 2
60 (8 electrodes)
Protective thermostat, fuse
Float SW, reed SW
Stationary type
measuring spoon
AFT-HVW10B
HIGH: 8 / MEDIUM: 5 / LOW: 2
Specifications
1
2
2
4